Double conversion 3kva ups power supply for home

  • Double conversion 3kva ups power supply for home
  • Double conversion 3kva ups power supply for home
  • Double conversion 3kva ups power supply for home
  • Double conversion 3kva ups power supply for home
  • Double conversion 3kva ups power supply for home
Double conversion 3kva ups power supply for home
  • MAXI
  • GUANGDONG
  • ≤200 units 20 days
  • 5000 units per month

Feature:
1.True double-conversion
2.Output power factor 0.9
3.Input power factor correction
4.50/60Hz Frequency Converter Mode
5.ECO mode energy saving
6.Emergency power off(EPO) function
7.Provides over voltage cut-off protection and surge immunity by MOV for full time equipment protection
8.High power factor charger up to 8A/12A capacity with very low ripple current when charging battery
9.Low input THDi to reduce power system pollution
10.Adjustable charger design to optimize battery performance
11.Smart battery charger design to optimize battery performance
12.Generator compatible
13.Optional HID Power Device USB Port

3kva ups


1.True double-conversion

2.Output power factor 0.9

3.Input power factor correction

4.50/60Hz Frequency Converter Mode

5.ECO mode energy saving

6.Emergency power off(EPO) function

7.Provides over voltage cut-off protection and surge immunity by MOV for full time equipment protection

8.High power factor charger up to 8A/12A capacity with very low ripple current when charging battery

9.Low input THDi to reduce power system pollution

10.Adjustable charger design to optimize battery performance

11.Smart battery charger design to optimize battery performance

12.Generator compatible

13.Optional HID Power Device USB Port


double conversion upsups power supply for home3kva upsdouble conversion ups

ups power supply for home


3kva ups


MODEL

MXT 3K(L)

PHASE

Single phase with ground

Capacity/Power(VA)

3KVA

INPUT

Nominal Voltage

105/110/115/120/127 VAC or 208/220/230/240 VAC

Voltage Range

110~300 VAC

Frequency Range

40Hz-70Hz

Power Factor

0.9

OUTPUT


Output Voltage

208/220V / 230V / 240V±1%

AC Voltage Regulation (Batt. Mode)

±1%

Frequency Range(Synchronized Range)

47-53Hz or 57-63Hz

Frequency Range ( Batt. Mode)

50Hz±0.1Hz or 60Hz±0.1Hz

Crest Factor

3:1

Harmonic Distortion

<3% THD(Linear Load)

Transfer Time

AC to DC

Zero

Inverter to Bypass

4ms(Typical)

ECO to Battery Mode

8ms(Typical),10ms(max)

Waveform (Batt.Mode)

Pure Sinewave

Topology

Online Double Conversion

EFFICIENCY

Efficiency at Full Load

93%@ battery fully charged

ECO Mode

96% battery full charged

BATTERY

Battery type

Maintenance free sealed lead acid battery

Numbers

8

Typical Recharge Time

5hours recover to 95% capacity for internal batteries

PROTECTION

Lighting & Surge, Over load, Short Circuit, AVR, under & over voltage, Battery low, Battery over charge & spike.

INDICATORS

LCD Panel

Load level, Battery level, AC mode Battery mode, Bypass mode and Fault indicator

ALARM

Battery Mode

Sounding every 5 seconds

Low Battery

Sounding every 2 seconds

Overload

Sounding every seconds

Fault

Continuously sounding

ENVIRONMENT


Humidity

20-95%RH 0-40(non-condensing)

Noise Level

Less than 50dBA 1 Meter

MANAGEMENT

Smart RS-232 or USB

Support Windows 2000/2003/XP/Visa/2008,Window7/8/10,Linux and MAC

Optional SNMP

Power management from SNMP manager and web browser

Cold Start

UPS started without AC Source

Control / Front panel

Multi-function LCD status and control console

Remote Monitoring

Remote Monitoring with SNMP Card: Enable with Rj-45 port network Connectivity.

STANDARD

EMC/Safety

EMC EN62040-2 C2 for CE models

Device Certification

ISO Certified


double conversion ups