Double conversion 3kva ups power supply for home
- MAXI
- GUANGDONG
- ≤200 units 20 days
- 5000 units per month
Feature:
1.True double-conversion
2.Output power factor 0.9
3.Input power factor correction
4.50/60Hz Frequency Converter Mode
5.ECO mode energy saving
6.Emergency power off(EPO) function
7.Provides over voltage cut-off protection and surge immunity by MOV for full time equipment protection
8.High power factor charger up to 8A/12A capacity with very low ripple current when charging battery
9.Low input THDi to reduce power system pollution
10.Adjustable charger design to optimize battery performance
11.Smart battery charger design to optimize battery performance
12.Generator compatible
13.Optional HID Power Device USB Port
1.True double-conversion
2.Output power factor 0.9
3.Input power factor correction
4.50/60Hz Frequency Converter Mode
5.ECO mode energy saving
6.Emergency power off(EPO) function
7.Provides over voltage cut-off protection and surge immunity by MOV for full time equipment protection
8.High power factor charger up to 8A/12A capacity with very low ripple current when charging battery
9.Low input THDi to reduce power system pollution
10.Adjustable charger design to optimize battery performance
11.Smart battery charger design to optimize battery performance
12.Generator compatible
13.Optional HID Power Device USB Port
MODEL | MXT 3K(L) | |
PHASE | Single phase with ground | |
Capacity/Power(VA) | 3KVA | |
INPUT | ||
Nominal Voltage | 105/110/115/120/127 VAC or 208/220/230/240 VAC | |
Voltage Range | 110~300 VAC | |
Frequency Range | 40Hz-70Hz | |
Power Factor | 0.9 | |
OUTPUT | ||
Output Voltage | 208/220V / 230V / 240V±1% | |
AC Voltage Regulation (Batt. Mode) | ±1% | |
Frequency Range(Synchronized Range) | 47-53Hz or 57-63Hz | |
Frequency Range ( Batt. Mode) | 50Hz±0.1Hz or 60Hz±0.1Hz | |
Crest Factor | 3:1 | |
Harmonic Distortion | <3% THD(Linear Load) | |
Transfer Time | AC to DC | Zero |
Inverter to Bypass | 4ms(Typical) | |
ECO to Battery Mode | 8ms(Typical),10ms(max) | |
Waveform (Batt.Mode) | Pure Sinewave | |
Topology | Online Double Conversion | |
EFFICIENCY | ||
Efficiency at Full Load | ≥93%@ battery fully charged | |
ECO Mode | ≥96% battery full charged | |
BATTERY | ||
Battery type | Maintenance free sealed lead acid battery | |
Numbers | 8 | |
Typical Recharge Time | 5hours recover to 95% capacity for internal batteries | |
PROTECTION | ||
Lighting & Surge, Over load, Short Circuit, AVR, under & over voltage, Battery low, Battery over charge & spike. | ||
INDICATORS | ||
LCD Panel | Load level, Battery level, AC mode Battery mode, Bypass mode and Fault indicator | |
ALARM | ||
Battery Mode | Sounding every 5 seconds | |
Low Battery | Sounding every 2 seconds | |
Overload | Sounding every seconds | |
Fault | Continuously sounding | |
ENVIRONMENT | ||
Humidity | 20-95%RH 0-40℃(non-condensing) | |
Noise Level | Less than 50dBA 1 Meter | |
MANAGEMENT | ||
Smart RS-232 or USB | Support Windows 2000/2003/XP/Visa/2008,Window7/8/10,Linux and MAC | |
Optional SNMP | Power management from SNMP manager and web browser | |
Cold Start | UPS started without AC Source | |
Control / Front panel | Multi-function LCD status and control console | |
Remote Monitoring | Remote Monitoring with SNMP Card: Enable with Rj-45 port network Connectivity. | |
STANDARD | ||
EMC/Safety | EMC EN62040-2 C2 for CE models | |
Device Certification | ISO Certified |