Industrial online Single Phase Ups 10kva

  • Industrial online Single Phase Ups 10kva
  • Industrial online Single Phase Ups 10kva
  • Industrial online Single Phase Ups 10kva
  • Industrial online Single Phase Ups 10kva
  • Industrial online Single Phase Ups 10kva
  • Industrial online Single Phase Ups 10kva
Industrial online Single Phase Ups 10kva
  • MAXI
  • GUANGDONG
  • ≤100 units 25 days
  • 800 units per month

MXD 11 10KVA Features:
It with the most advanced phase-balanced technology, and it features best stability, even if loss-phase, it could still operate at normal condition, so it's suitable for any worse power supply, double conversion, pure sine wave output line design could supply the low-distortion pure sine wave power, so it can provide the best power protection to the user's equipment.

10kva single phase ups


1.Intelligent control of multiple CPU

2.Humanized display interface

3.High-intelligence network control

4.Intelligent battery management

5.Fault detection and alarming


low frequency ups 10kva

10kva single phase upslow frequency ups 10kva10kva single phase ups

low frequency ups 10kva

10kva single phase ups


Index

MXD11 10K

Input

Input voltage

Rated voltage

220VAC

Phase

Single phase with ground

Turn on voltage range

220±25% VAC

Bypass voltage range

220VAC±25%

Bypass low loss

165VAC

Bypass low comeback

Low loss +10VAC

Bypass high loss

275VAC

Bypass high comeback

High loss-10VAC

Line low loss/comeback

(165±5) VAC /(180±5) VAC

Line high loss/comeback

(275±5)VAC/(260±5)VAC

Input frequency

Rated frequency

50Hz

Frequency low loss

(40~49)±0.2Hz(default:46Hz)

Frequency low comeback

Frequency low loss + 0.5Hz

Frequency high loss

(51~60)±0.2Hz(default:54Hz)

Frequency high comeback

Frequency high loss - 0.5Hz

Input power factor

Input power factor

Max 0.8

Generator

Support generator input

Input current

Rated current

153A

Input protection

Rated protection

160A

Output

Output power

VA/watt

20KVA/16KW

Rated voltage

220VAC

Phase

Single phase with ground

Voltage range

200/208/220/230/240VAC

Voltage regulation

±2%

Voltage distortion

≤8%

≤3%

DC offset

≤200mV

Transient response

≤9%

≤6%

Transient recovery

≤60ms voltage recovery to 90%

Bypass output before turn-on

Yes

Crest ration

3:1

Output frequency range

Line mode

1.Same as input frequency(46Hz~54Hz)

2.50Hz(Input frequency>54Hz or Input frequency<46Hz)

Battery mode

(50+0.1) Hz

Slew rate

1 Hz/Sec

Efficiency

Line mode

> 87%

Battery mode

> 88%

Overload

 

line mode/battery mode 

Overload warning only

2Minthen transfer to bypass and alarm.

30S,then transfer to bypass and alarm.

0.5S,then transfer to bypass and alarm.

Automatically recovery

Yes

Short protection

Line/battery mode

Cut off output and alarm after 3S

Transfer time

Line to battery mode

0mS

Battery to line mode

0mS

Line to bypass mode

<1mS

Bypass to line mode

<1mS

Battery and charger

Battery

Rated voltage

192VDC 

Protection

Low alarm voltage / comeback voltage

(180.8V±4V)/ (188.8V±4V)

Shutdown voltage

(176V±4V)/ (184V±4V)

(160V±4V)/ (168V±4V)

Battery protection

Overcharge protection

(250V±4V)

Battery test

Battery weak

Support

Battery fault

Support

Charger

Output voltage

(220±2)VDC

Charge time

Determined by battery capacity

Charge current

7A

Interface

Alarm silence

Support

DC power turn-on

Support

Automatically restart

Support

alarm

Battery mode

Beep/4s

Battery low/charger fault

Beep/1s

UPS fault

Continuously beep

Overload

Beep/1s

Bypass mode

Beep/2Min

Communication

RS232/ RS485 interface

Support

Output dry contactor

Support

Intelligent slot

Support

Monitor software

Appending with UPS

Cooling

Force air cooling

Display

LCD displays UPS status

Support

Environment

Work temperature

0℃~40℃

Altitude

<1000m

Audible noise

55dB

Storage temperature

-15℃~45℃

Work humidity

20%~95%

Standard

EMS/EMI

Conducted

IEC EN62040-02

Radiated

Anti-interference

IEC 61000-4-2.4.5 Level IV, IEC61000-4-3 Level III

Safety

Safety

GB4943-2001/IEC62040-1

Transportation

Drop test

GB-T4857-18

Vibration test

B-WR1-129(GB-T14715-93)

Machinery features

Connection

Inlet

Wiring terminal block

Outlet

Wiring terminal block

External battery slot

Wiring terminal block

Size

UPS net weight and size

W*H*D(mm)

370*900*655

455*1055*830

Net weight(Kg)

155kg

160kg


Optional functions

60Hz

Support

Converter mode

Support

ECO mode

Support

EPO mode

Support


low frequency ups 10kva



Get the latest price? We'll respond as soon as possible(within 12 hours)