RMT 1KVA 110V Feature:
1.Ture double-conversion
2.3-level inverter technology
3.Output voltage regulation <1%
4.50Hz/60Hz frequency converter mode
5.ECO mode energy saving
6.Overvoltage and undervoltage protections and surge immunity by MOV for full time equipment protection
7.High power factor charger with very low ripple current when charging batteries
8.Low input THDi to reduce power system pollution
9.Rack mount to tower convertible
10.Optional SNMP card

1 kva ups rack mount


1. Ture double-conversion

2. 3-level inverter technology

3. Output voltage regulation <1%

4. 50Hz/60Hz frequency converter mode

5. ECO mode energy saving

6. Overvoltage and undervoltage protections and surge immunity by MOV for full time equipment protection

7. High power factor charger with very low ripple current when charging batteries

8. Low input THDi to reduce power system pollution

9. Rack mount to tower convertible

10. Optional SNMP card


rack mount ups

rack mount ups


MODEL

RMT 1KVA(Splus

RMT 2KVA(Splus

RMT 3KVA(Splus

PHASE

Single phase with ground

CAPACITY

1000VA/800W

2000VA/1600W

3000VA/2400W

INPUT

Nominal Voltage

110Vac

Voltage Range

60-138VAC ±5% at 50% load

80-138VAC ±5% at 100% load

Frequency Range

40Hz-70Hz(46-54Hz default 50Hz;56-64Hz default 60Hz)

Power Factor

≥0.99@nominal voltage(100% load)

THDi%

10%

OUTPUT

Output Voltage

100/110/115/120/127 VAC)adjustable on LCD panel

AC Voltage Regulation

±2%

FrequencyRange

(Synchronized Range)

47-53 Hz or 57-63 Hz

Frequency Range(Batt.Mode)

50 Hz±0.1 Hz or 60 Hz±0.1 Hz

Current Crest Ratio

3:1

Harmonic Distortion

THD (Linear Load)≤4%,THD (Non-linear Load)≤7%

Transfer Time

AC to DC

zero

Inverter to Bypass

4ms (Typical)

ECO to Battery Mode

8ms (Typical),10 ms (max)

Waveform

Pure Sinewave

EFFICIENCY

Line Mode

≥89%@battery full charged

≥91%@battery full charged

ECO Mode

≥96%@battery full charged

Battery Mode

≥86%

BATTERY

Battery Type

12V/7AH

12V/7AH

12V/7AH

Numbers

3

6

8

Typical Recharge Time

5hours recover to 95% capacity for internal battery

Charging Current

1-3KVA   1A

1-3KS  5A

Charging Voltage

41.25VDC±1%

82.5VDC±1%

110VDC±1%

INDICATORS

LCD Panel

Load level,Battery level, AC mode,Battery mode,Bypass mode,and Fault indicator

ALARM

Battery Mode

beeps every 5 seconds

Low Battery

beeps every 2 seconds

Overload

Beeps every seconds

Fault

Continuously beeps

PHYSICAL

Dimension,D*W*H(mm)

476*482.6*88

476*482.6*88

Net Weight (long backup )(kgs)

8

10

11

Net weight (w/built-in batteries)(kgs)

15

28

32.5

ENVIRONMENT

Humidity

20-95%RH@0-40℃(non-condensing)

Noise Level

Less than 50dBA @ 1 Meter

MANAGEMENT

Smart RS-232 or USB

Support Windows2000/2003/XP/Vista/2008,Windows7/8/10,Linux and MAC

Optional SNMP

Power management from SNMP manager and web browser

STANDARD

EMC/Safety

EMC EN62040-2 C2 for CE models