Online Uninterrupted Power Supply 100kva
- MAXI
- GUANGDONG
- ≤100 units 25 days
- 100 units per month
MXD33 100KVA Feature:
1. Prefect protection
2.DSP full digital control technology,making control accurate,Fast ,reliable and stable
3.Powerful intelligent monitoring function
4.The output can be connected to an inductive load
5.Can be used with generators
6.The true online double conversion design provides the best power guarantee for the user's load equipment.
7.User-friendly LCD+LED dual display ,LED can visually display the working status of the UPS.
1.Advanced intelligent CPU control
2.100% unbalanced protection design
3.Intelligent charging management
4.Special short circuit protection design
5.Output with isolation transformer to ensure complete isolation of load and utility grid
Model | 100K |
Input | |
Main input supply | |
Rated voltage | 380VAC (Line voltage) /220VAC (Phase voltage) |
Input wiring | 3Ф + N + E(Protective earth) |
Voltage range | (165±5~275±5)VAC (Phase voltage) |
Low voltage lose/recovery | (165±5) VAC / (180±5) VAC (Phase voltage) |
High voltage lose/recovery | (275±5) VAC/ (260±5) VAC (Phase voltage) |
Bypass | |
Rated voltage | 380/220VAC |
Input wiring | 3Ф + N + E (Protective earth) |
Voltage range | (165±5~275±5) VAC (Phase voltage) |
Low voltage lose/recovery | (165±5) VAC / (180±5) VAC (Phase voltage) |
High voltage lose/recovery | (275±5) VAC/ (260±5)VAC (Phase voltage) |
Input frequency | |
Rated frequency | 50Hz/60Hz |
Low frequency lost | 46Hz/56Hz |
Low frequency recovery | 46+0.5Hz/56+0.5Hz |
High frequency lost | 54Hz/64Hz |
High frequency recovery | 54-0.5Hz/64-0.5Hz |
Input performance | |
Input power factor | 0.8 (220V、Linear full load ) |
Generator input | Support (Generator rated power ≥ 2 UPS rated power) |
Input current | |
Rated current | 250A |
Output | |
Output power | |
Rated VA/Watt | 100KVA/80KW |
Rated voltage | 380VAC(Line voltage)/220VAC (Phase voltage) |
Output voltage range | 200/208/220/230/240VAC (Output power reduces to 90% 208/200V) |
Voltage regulation | ±2 % |
THD V | ≤8 % |
≤3 % | |
Phase regulation | 120±1° |
Voltage transient response | ≤9% (Linear load 0%~100%~0%) |
Transient response recovery time | ≤60mS (Nonlinear load) recovery to 90% |
Bypass before turn on | Yes |
Model | 100K |
Crest ratio | 3 : 1 |
Output frequency range | |
Line mode | 46Hz~54Hz (The same as input frequency) |
50Hz (Line frequency>54Hz or line frequency<46Hz) | |
Battery mode | (50+0.1) Hz |
Slew rate | 1 Hz/Sec |
Efficiency | |
Line mode | >85% |
Battery mode | >90% |
Overload function | |
Line mode/ Battery mode | Overload warning only; 105%±5%≤load |
2Min, then transfer to bypass and alarm; 105%±5%<load≤125%±5% | |
30S, then transfer to bypass and alarm; 125%±5%<load≤150%±5% | |
0.5S, then transfer to bypass and alarm; load>150%±5% | |
Automatically recovery | Yes |
Short protection | |
Line mode/ Battery mode | Cut off output after 3s |
Transfer time | |
Line mode to Battery mode | 0mS |
Battery mode to line mode | 0mS |
Line mode to Bypass mode | <1mS |
Bypass mode to line mode | <1mS |
Battery and Charger | |
Battery | |
Rated voltage | 384VDC |
Protection | |
Low battery alarm/recovery | (361.6V±4V)/ (377.6V±4V) |
Battery shutdown voltage | (320V±4V)/ (336V±4V) |
Battery protection | |
Battery overcharge protection | (475V±4V) |
Battery detect | |
Battery missing | Support |
Battery failure | Support |
Charge | |
Float charge voltage | (440±2)VDC |
Charge time | Depending on the battery capacity |
Charge current | 10A ( Adjustable ) |
Interface | |
Alarm mute | Support |
DC boot | Support |
Auto Reboot | Support |
Alarm function | |
Battery mode | Beep once every 4 second |
Battery low voltage / Charger fault | Beep once every second |