Online Ups 1kva With Isolation Transformer
- MAXI
- GUANGDONG
- ≤200 units 20 days
- 5000 units per month
Online Ups 1kva With Isolation Transformer
This product is the best office supply partnersto provide the best pure sine wave power. This series UPS can be used in personal computers, telecommunications, medical equipment, banking systems, rail transport, electricity, research and so on.
1. Load power factor is 0.96, adaptive for the develplent trend fo electrical
2. Equipment and the load capacity is more strong
3. Active input power factor correction (PFC), input power factor is over 0.98
4. Wide input voltage and frequency range, adaptive for extreme adverse grid environment of remote areas
5. It can be connected with generators
6. Zero transfer time effective ensures the safety and reliability of load operation
MODEL | 1K-ISO TX | ||||
CAPACITY | VA/W | 1000VA/900W | |||
INPUT | Input isolation transformer | connected on input end | |||
Voltage Range | 120~264VAC | ||||
Frequency Range | default 50Hz (46-54)Hz / default 60Hz (56-64)Hz | ||||
Phase | Single phase with Ground | ||||
Power Factor | ≥0.96 | ||||
OUTPUT
| Voltage | 220/230/240VAC | |||
Voltage Regulation | ±2% | ||||
Frequency (Synchronized Range) | 47-53Hz/57-63Hz | ||||
Frequency (BAT Mode) | 50/60Hz±0.2Hz | ||||
Current Crest Ratio | 3:1 | ||||
Harmonic Distortion | <3% THD(Linear Load) | ||||
<5% THD(Non-Linear Load ) | |||||
Output Waveform | Pure Sine Wave | ||||
Overload Capacity | Line Mode
| overload warning only @105%±5% <load 10s, then transfer to bypass and alarm @105%±5%<load≤120%±5% 300ms, then transfer to bypass and alarm @load>120%±5%
| |||
EFFICIENCY | Line Mode | >75.7% | |||
BAT Mode | >84.5% | ||||
ECO Mode | >84.3% | ||||
BATTERY | Number of Batteries | 3 | |||
Battery Type | 12V/7AH | ||||
Backup Time (Full Load) | >9 minutes | ||||
Recharge Time | 7 hours to 90% | ||||
Charging Current | 1A | ||||
TRANSFER TIME | BAT <--> LINE | 0ms | |||
INV <--> BYPASS | <4ms | ||||
INV-->ECO | <4ms | ||||
ECO--> INV | <10ms | ||||
INDICATOR | LCD | Load/Battery/Input/Output/Operating Mode Information | |||
AUDIBLE ALARM | Battery Mode | beeps every 4 seconds | |||
Battery Low | beeps every second | ||||
Fault | Continuously beeping | ||||
Overload Capacity | beeps twice every second | ||||
MECHANICAL | Dimension WxDxH(mm) | 180x400x260 | |||
Net Weight (Kg) | 19.5 | ||||
ENVIRONMENT | Operation Environment | 0-40℃ | |||
Relative Humidity | 0-95% (Non-Condensing) | ||||
Noise Level | <54dB @ Front 1 meter | ||||
INTERFACE | USB/RS232 | Software supports Windows Family, Linux, Sun Solaris, IBM Aix, Compaq True64, SGIIRIX, FreeBSD, HP-UX, MAC | |||
External Slot | Optional, External Type of SNMP/AS400 Card | ||||
EPO | Emergency Power Off |