MXD33 60KVA Feature:
The 60 KVA UPS online pure sine wave battery backup uninterruptible power supply (UPS) and power conditioner with surge protection automatically provides defense against power problems. Give your electronics longer life while protecting them from harmful dirty power problems that may otherwise damage or degrade their performance.
1.Built-in Output Isolation Transformer
2.It adopts industrial grade powerful high-speed centrifugal fan for heat dissipation, intelligent speed regulation and low noise
3.The output waveform has high quality and good load characteristics
4.IGBT uses space vector modulation technology to greatly improve DC voltage utilization and reduce the harmonic content, the same capacity battery backup time is longer.
5.The human-machine interface adopts a liquid crystal touch screen
Model | 60K |
Input | |
Main input supply | |
Rated voltage | 380VAC (Line voltage) /220VAC (Phase voltage) |
Input wiring | 3Ф + N + E(Protective earth) |
Voltage range | (165±5~275±5)VAC (Phase voltage) |
Low voltage lose/recovery | (165±5) VAC / (180±5) VAC (Phase voltage) |
High voltage lose/recovery | (275±5) VAC/ (260±5) VAC (Phase voltage) |
Bypass | |
Rated voltage | 380/220VAC |
Input wiring | 3Ф + N + E (Protective earth) |
Voltage range | (165±5~275±5) VAC (Phase voltage) |
Low voltage lose/recovery | (165±5) VAC / (180±5) VAC (Phase voltage) |
High voltage lose/recovery | (275±5) VAC/ (260±5)VAC (Phase voltage) |
Input frequency | |
Rated frequency | 50Hz/60Hz |
Low frequency lost | 46Hz/56Hz |
Low frequency recovery | 46+0.5Hz/56+0.5Hz |
High frequency lost | 54Hz/64Hz |
High frequency recovery | 54-0.5Hz/64-0.5Hz |
Input performance | |
Input power factor | 0.75 (220V、Linear full load ) |
Generator input | Support (Generator rated power ≥ 2 UPS rated power) |
Input current | |
Rated current | 135A |
Output | |
Output power | |
Rated VA/Watt | 60KVA/ 48KW |
Rated voltage | 380VAC(Line voltage)/220VAC (Phase voltage) |
Output voltage range | 200/208/220/230/240VAC (Output power reduces to 90% 208/200V) |
Voltage regulation | ±2 % |
THD V | Full RCD load |
Linear full load | |
Phase regulation | 120±1° |
Voltage transient response | ≤9% (Linear load 0%~100%~0%) |
Transient response recovery time | ≤60mS (Nonlinear load) recovery to 90% |
Bypass before turn on | Yes |
Model | 60K |
Crest ratio | 3 : 1 |
Output frequency range | |
Line mode | 46Hz~54Hz /56Hz~64Hz(The same as input frequency) |
50Hz/60Hz (Line frequency>(54Hz /64Hz) or line frequency<(46Hz/56Hz) | |
Battery mode | (50+0.1) Hz/(60+0.1) Hz |
Slew rate | 1 Hz/Sec |
Efficiency | |
Line mode | > 90% |
Battery mode | > 93% |
Overload function | |
Line mode/ Battery mode | Overload warning only; 105%±5%≤load |
2Min, then transfer to bypass and alarm; 105%±5%<load≤125%±5% | |
30S, then transfer to bypass and alarm; 125%±5%<load≤150%±5% | |
0.5S, then transfer to bypass and alarm; load>150%±5% | |
Automatically recovery | Yes |
Short protection | |
Line mode/ Battery mode | Cut off output after 3s |
Transfer time | |
Line mode to Battery mode | 0mS |
Battery mode to line mode | 0mS |
Line mode to Bypass mode | <1mS |
Bypass mode to line mode | <1mS |
Battery and Charger | |
Battery | |
Rated voltage | 384VDC |
Protection | |
Low battery alarm/recovery | (361.6V±4V)/ (377.6V±4V) |
Battery shutdown voltage | (320V±4V)/ (336V±4V) |
Battery protection | |
Battery overcharge protection | (475V±4V) |
Battery detect | |
Battery missing | Support |
Battery failure | Support |
Charge | |
Float charge voltage | (440±2)VDC |
Charge time | Depending on the battery capacity |
Charge current | 10A ( Adjustable ) |
Interface | |
Alarm mute | Support |
DC boot | Support |
Auto Reboot | Support |
Alarm function | |
Battery mode | Beep once every 4 second |
Low battery voltage / Charger fault | Beep once every second |
Model | 60K |
UPS fault | Beep continuously |
Overload | Beep once every second |
Bypass | Beep once every 2 minute |
Communication interface | |
RS232/ RS485 | Support |
Output dry contact | Support |
Intelligent slot | Support SNMP/AS400 |
Supervisory software | Support |
Cooling way | |
Forced air cooling | |
Show | |
LCD+LED | |
Environment | |
Working temperature | 0℃~40℃ |
Altitude | <1000m |
Noise | ≤70dB |
Storage temperature | -15℃~45℃ |
Work humidity | 20% ~ 95% |
Standard | |
EMS/EMI | |
Anti-interference | IEC 61000-4-2.4.5 Level IV, IEC61000-4-3 Level III |
Conduction | IEC62040-02 |
Radiation | |
Safety | |
Safety | GB4943-2001/IEC62040-1 |
Mechanical properties | |
Connection | |
Input | Terminal blocks |
Output | Terminal blocks |
Battery interface | Terminal blocks |
Other function | |
60Hz | Support |
Frequency mode | Support |
ECO | Support(option) |
EPO | Support |