Low Frequency Three Phase Ups 40kva

  • Low Frequency Three Phase Ups 40kva
  • Low Frequency Three Phase Ups 40kva
  • Low Frequency Three Phase Ups 40kva
  • Low Frequency Three Phase Ups 40kva
Low Frequency Three Phase Ups 40kva
  • MAXI
  • GUANGDONG
  • ≤100 units 25 days
  • 100 units per month

MXD33 40KVA Feature:
It is the collection digitization,informationization, network as one of high intelligent products, with powerful information acquisition system,signal processing system, detection system and perfect protection system. Widely used in all kinds of electricity environment, Personalized design, powerful human-machine conversation function. Visual display and state monitoring interface, make each user operate simply and conveniently.

40kva three phase ups


1.DSP full digital control technology, pure online double conversion architecture, with strong carrying capacity

2.Input power factor up to 0.75, low harmonic current, environmental protection, high efficiency and energy saving;

3.Wide input voltage range, 50Hz/60Hz grid system adaptive, suitable for various environmental grids

4.Rich communication interface, including RS232, RS485, USB, dry contact, and SNMP (optional) card

5.Large LCD touch widescreen display for a friendly human- machine interface


low frequency ups

three phase ups40kva three phase ups

low frequency ups


Model

40K

Input

Main input supply

Rated voltage

380VAC (Line voltage) /220VAC (Phase voltage)

Input wiring

3Ф + N + E(Protective earth)

Voltage range

(165±5~275±5)VAC (Phase voltage)

Low voltage lose/recovery

(165±5) VAC / (180±5) VAC (Phase voltage)

High voltage lose/recovery

(275±5) VAC/ (260±5) VAC (Phase voltage)

Bypass

Rated voltage

380/220VAC

Input wiring

3Ф + N + E (Protective earth)

Voltage range

(165±5~275±5) VAC (Phase voltage)

Low voltage lose/recovery

(165±5) VAC / (180±5) VAC (Phase voltage)

High voltage lose/recovery

(275±5) VAC/ (260±5)VAC (Phase voltage)

Input frequency

Rated frequency

50Hz/60Hz

Low frequency lost

46Hz/56Hz

Low frequency recovery

46+0.5Hz/56+0.5Hz

High frequency lost

54Hz/64Hz

High frequency recovery

54-0.5Hz/64-0.5Hz

Input performance

Input power factor

0.75 (220VLinear full load )

Generator input

Support (Generator rated power  2 UPS rated power)

Input current

Rated current

91A

Output

Output power

Rated VA/Watt

40KVA/ 32KW

Rated voltage

380VAC(Line voltage)/220VAC (Phase voltage)

Output voltage range

200/208/220/230/240VAC (Output power reduces to 90% 208/200V)

Voltage regulation

±2 %

THD V

Full RCD load

Linear full load

Phase regulation

120±1°

Voltage transient response

≤9% (Linear load 0%~100%~0%)

Transient response recovery time

≤60mS (Nonlinear load) recovery to 90%

Bypass before turn on

Yes

Model

40K

Crest ratio

3 : 1

Output frequency range

Line mode

46Hz~54Hz /56Hz~64Hz(The same as input frequency)

50Hz/60Hz (Line frequency>(54Hz /64Hz) or line frequency<(46Hz/56Hz)

Battery mode

(50+0.1) Hz/(60+0.1) Hz

Slew rate

1 Hz/Sec

Efficiency

Line mode

> 89%

Battery mode

> 0.92%

Overload function

Line mode/ Battery mode

Overload warning only; 105%±5%≤load

2Min, then transfer to bypass and alarm; 105%±5%<load≤125%±5%

30S, then transfer to bypass and alarm; 125%±5%<load≤150%±5%

0.5S, then transfer to bypass and alarm; load>150%±5%

Automatically recovery

Yes

Short protection

Line mode/ Battery mode

Cut off output after 3s

Transfer time

Line mode to Battery mode

0mS

Battery mode to line mode

0mS

Line mode to Bypass mode

<1mS

Bypass mode to line mode

<1mS

Battery and Charger

Battery

Rated voltage

384VDC

Protection

Low battery alarm/recovery

(361.6V±4V)/ (377.6V±4V)

Battery shutdown voltage

(320V±4V)/ (336V±4V)

Battery protection

Battery overcharge protection

(475V±4V)

Battery detect

Battery missing

Support

Battery failure

Support

Charge

Float charge voltage

(440±2)VDC

Charge time

Depending on the battery capacity

Charge current

10A ( Adjustable )

Interface

Alarm mute

Support

DC boot

Support

Auto Reboot

Support

Alarm function

Battery mode

Beep once every 4 second

Low battery voltage / Charger fault

Beep once every second

Model

40K

Crest ratio

3 : 1

                       Output frequency range

Line mode

46Hz~54Hz (The same as input frequency)

50Hz (Line frequency>54Hz or line frequency<46Hz)

Battery mode

(50+0.1) Hz

Slew rate

1 Hz/Sec

                      Efficiency

Line mode

>85%

Battery mode

>90%

                      Overload function

Line mode/ Battery mode

Overload warning only; 105%±5%≤load

2Min, then transfer to bypass and alarm; 105%±5%<load≤125%±5%

30S, then transfer to bypass and alarm; 125%±5%<load≤150%±5%

0.5S, then transfer to bypass and alarm; load>150%±5%

Automatically recovery

Yes

                    Short protection

Line mode/ Battery mode

Cut off output after 3s

                     Transfer time

Line mode to Battery mode

0mS

Battery mode to line mode

0mS

Line mode to Bypass mode

<1mS

Bypass mode to line mode

<1mS

                       Battery and Charger

                       Battery

Rated voltage

384VDC

                     Protection

Low battery alarm/recovery

(361.6V±4V)/ (377.6V±4V)

Battery shutdown voltage

(320V±4V)/ (336V±4V)

                       Battery protection

Battery overcharge protection

(475V±4V)

                     Battery detect

Battery missing

Support

Battery failure

Support

                     Charge

Float charge voltage

(440±2)VDC

Charge time

Depending on the battery capacity

Charge current

10A ( Adjustable )

                      Interface

Alarm mute

Support

DC boot

Support

Auto Reboot

Support

                     Alarm function

Battery mode

Beep once every 4 second

Battery low voltage / Charger fault

Beep once every second