Ups Backup Power 40kva Three Phase 220v

  • Ups Backup Power 40kva Three Phase 220v
  • Ups Backup Power 40kva Three Phase 220v
Ups Backup Power 40kva Three Phase 220v
  • MAXI
  • GUANGDONG
  • ≤100 units 25 days
  • 200 units per month

MXD31 40KVA Feature:
1.Adopt the latest three-level inverter technology
2.Advanced DSP digital control system
3.Active input Power Factor Correction (PFC)
4.Super wide input frequency range
5.Output power factor 0.8
6.Powerful expansibility features

40kva three phase ups


1. High level battery reliability:

- Automatic battery test

- Battery care, Battery life span can be increased approximately by 20% more

2. Back feed protection: to avoid energy feeding back into the mains supply

3. Bypass may be deactivated to allow operation as a frequency converter (at 50 or 60 Hz), or as stabilizer

4. Easy to maintain (front access)

5. Reliable, filtered, stabilised and regulated sine wave output (double on-line concersion technology VFI according to EN50091-3 specifications) with filters for atmospheric disturbance suppression

6. High reliability: IGBT technology, full microprocessor control with no-break static and manual bypass

7. High level diagnostics: event log with 128 messages, states, measurements and alarms-available from the built-in LCD in several languages

8. The UPS may be configured with the RS232 serial port (flash up-gradable )

220v upsups backup power40kva three phase ups

220v ups


MODEL

MXD 40K

Input Mains

Rated voltage(V)

380Vac 3phase+N

Rated voltage&Range(v)

380V±25%

Frequency&Range(Hz)

50/60Hz±4Hz

Bypass Input

Rated voltage(V)

220V/230V

Rated voltage&Range(v)

380V±25%

Frequency&Range(Hz)

50/60Hz±4Hz

Output

Rated Power

40KVA/32KW

Rated Voltage(V)

220V/230V

Rated Voltage&Stability

220V/230V±2%

THDV

Linear Load

≤3%

Non-linear Load

≤8%

Output Power factor

0.8

Tracking Frequency&Range(Hz)

50/60Hz±4Hz

Frequency&Stability

(Battery Inverter)

(50/60+0.1)Hz

Overload Capability

Less than 105%±5% for overload alarm;105%±5%~125%±5% for 2 minutes

125%±5%~150%±5% for 30 second; more than 150%±5% for 0.5 second

Converting time

(Normal Mode)

<1ms

Converting time(ECO Mode)

<25ms

System Efficiency(Linear Load)

≥85

System Efficiency(ECO Mode)

≥96%

Physical

W*D*H (mm)

455*830*1055

N.W. (kg)

184

System

Display

LCD/LED

EMS/EMI

Transmission

IEC 62040-02

Radiation

IEC 62040-02

Resisting Interference

IEC 61000-4-2.4.5 Level IV, IEC 61000-4-3 Level III

Safety Requirements

GB4943-2001/IEC62040-1

Noise Level(1M)

≤55dB

Isolate Impedance(Ω)

>2M(500VDC)

Surge Current Protection

IEC60664-1 IV

Environment

Operating Temperatures

0℃~40℃

Elevation

<1000m

Storing Temperatures

-15℃~45℃

Operation Humidity

20%~95%

Battery voltage

384VDC





Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right