Industrial Sing Phase Online Ups 15kva
- MAXI
- GUANGDONG
- ≤100 units 25 days
- 200 units per month
MXD 11 15KVA Feature:
Effectively solves power outages, high-voltage mains, low-voltage mains, instantaneous voltage drops,Power problems such as ringing, high voltage pulses, surge voltage, harmonic distortion, clutter, frequency fluctuations, etc.Provide the best power environment for the load.
1.Double conversion online design, output zero transfer time
2.Adopt DSP digital control, excellent performance indicators, make the control system more stable and reliable
3.Using active power factor correction (PFC), the input power is close to 1, large reduced pollution to the mains grid
4.With LCD+LED real-time display, users can intuitively understand the UPS operating status
5.When the utility is interrupted, the UPS is discharged to the battery in battery mode; when the city power is restored,the UPS can be powered on automatically and the battery is charged for unattended operation.
Index | MXD11 15K |
Input | |
Input voltage | |
Rated voltage | 220VAC |
Phase | Single phase with ground |
Turn on voltage range | 220±25% VAC |
Bypass voltage range | 220VAC±25% |
Bypass low loss | 165VAC |
Bypass low comeback | Low loss +10VAC |
Bypass high loss | 275VAC |
Bypass high comeback | High loss-10VAC |
Line low loss/comeback | (165±5) VAC /(180±5) VAC |
Line high loss/comeback | (275±5)VAC/(260±5)VAC |
Input frequency | |
Rated frequency | 50Hz |
Frequency low loss | (40~49)±0.2Hz(default:46Hz) |
Frequency low comeback | Frequency low loss + 0.5Hz |
Frequency high loss | (51~60)±0.2Hz(default:54Hz) |
Frequency high comeback | Frequency high loss - 0.5Hz |
Input power factor | |
Input power factor | Max 0.8 |
Generator | Support generator input |
Input current | |
Rated current | 115A |
Input protection | |
Rated protection | 160A |
Output | |
Output power | |
VA/watt | 15KVA/12KW |
Rated voltage | 220VAC |
Phase | Single phase with ground |
Voltage range | 200/208/220/230/240VAC |
Voltage regulation | ±2% |
Voltage distortion | ≤8% |
≤3% |
DC offset | ≤200mV |
Transient response | ≤9% |
≤6% | |
Transient recovery | ≤60ms voltage recovery to 90% |
Bypass output before turn-on | Yes |
Crest ration | 3:1 |
Output frequency range | |
Line mode | 1.Same as input frequency(46Hz~54Hz) |
2.50Hz(Input frequency>54Hz or Input frequency<46Hz) | |
Battery mode | (50+0.1) Hz |
Slew rate | 1 Hz/Sec |
Efficiency | |
Line mode | > 87% |
Battery mode | > 88% |
Overload | |
line mode/battery mode | Overload warning only |
2Min,then transfer to bypass and alarm. | |
30S,then transfer to bypass and alarm. | |
0.5S,then transfer to bypass and alarm. | |
Automatically recovery | Yes |
Short protection | |
Line/battery mode | Cut off output and alarm after 3S |
Transfer time | |
Line to battery mode | 0mS |
Battery to line mode | 0mS |
Line to bypass mode | <1mS |
Bypass to line mode | <1mS |
Battery and charger | |
Battery | |
Rated voltage | 192VDC |
Protection | |
Low alarm voltage / comeback voltage | (180.8V±4V)/ (188.8V±4V) |
Shutdown voltage | (176V±4V)/ (184V±4V) |
(160V±4V)/ (168V±4V) | |
Battery protection | |
Overcharge protection | (250V±4V) |
Battery test | |
Battery weak | Support |
Battery fault | Support |
Charger | |
Output voltage | (220±2)VDC |
Charge time | Determined by battery capacity |
Charge current | 7A |
Interface | |
Alarm silence | Support |
DC power turn-on | Support |
Automatically restart | Support |
alarm | |
Battery mode | Beep/4s |
Battery low/charger fault | Beep/1s |
UPS fault | Continuously beep |
Overload | Beep/1s |
Bypass mode | Beep/2Min |
Communication | |
RS232/ RS485 interface | Support |
Output dry contactor | Support |
Intelligent slot | Support |
Monitor software | Appending with UPS |
Cooling | |
Force air cooling | |
Display | |
LCD displays UPS status | Support |
Environment | |
Work temperature | 0℃~40℃ |
Altitude | <1000m |
Audible noise | ≤55dB |
Storage temperature | -15℃~45℃ |
Work humidity | 20%~95% |
Standard | |
EMS/EMI | |
Conducted | IEC EN62040-02 |
Radiated | |
Anti-interference | IEC 61000-4-2.4.5 Level IV, IEC61000-4-3 Level III |
Safety | |
Safety | GB4943-2001/IEC62040-1 |
Transportation | |
Drop test | GB-T4857-18 |
Vibration test | B-WR1-129(GB-T14715-93) |
Machinery features | |
Connection | |
Inlet | Wiring terminal block |
Outlet | Wiring terminal block |
External battery slot | Wiring terminal block |
Size | |
UPS net weight and size | |
W*H*D(mm) | 370*900*655 |
Net weight(Kg) | 155kg |
Optional functions | |
60Hz | Support |
Converter mode | Support |
ECO mode | Support |
EPO mode | Support |