MXD 11 3KVA Features:
High reliability: IGBT technology, full microprocessor control with no-break static and manual bypass
High level diagnostics: event log with 128 messages, states, measurements and alarms-available from the built-in LCD in several languages
The UPS may be configured with the RS232 serial port (flash up-gradable)
1.Advanced DSP digital control technology
2.LCE+LED display
3.With output isolation transformer
4.DC cold start function
5.Frequency self-adaptive system
6.Special short circuit protection design
7.Support mobile phone monitoring card,can monitor ups data through mobile phone APP
Index | MXD11 3KVA | Comments |
Input | ||
Input voltage | ||
Rated voltage | 220VAC | |
Phase | Single phase with ground | |
Turn on voltage range | 220±25% VAC | |
Bypass voltage range | 220VAC±25% | Phase voltage; Could be adjusted by software.
|
Bypass low loss | 165VAC | |
Bypass low comeback | Low loss +10VAC | |
Bypass high loss | 275VAC | |
Bypass high comeback | High loss-10VAC | |
Line low loss/comeback | (165±5) VAC /(180±5) VAC | |
Line high loss/comeback | (275±5)VAC/(260±5)VAC | |
Input frequency | ||
Rated frequency | 50Hz | Could be adjusted by software. |
Frequency low loss | (40~49)±0.2Hz(default:46Hz) | |
Frequency low comeback | Frequency low loss + 0.5Hz | |
Frequency high loss | (51~60)±0.2Hz(default:54Hz) | |
Frequency high comeback | Frequency high loss - 0.5Hz | |
Input power factor | ||
Input power factor | Max 0.8 | |
Generator | Support generator input | Generator rating≥2*UPS rating |
Input current | ||
Rated current | 24A | |
Input protection | ||
Rated protection | 32A | |
Output | ||
Output power | ||
VA/watt | 3KVA/2.4KW | |
Rated voltage | 220VAC | Sine wave |
Phase | Single phase with ground | |
Voltage range | 200/208/220/230/240VAC | Could be adjusted by software. 10% derating for 208VAC/200VAC. |
Voltage regulation | ±2% | |
Voltage distortion | ≤8% | Full RCD load |
≤3% | Full R load |
Index | MXD11 10K | Comments | ||
Environment | ||||
Work temperature | 0℃~40℃ | |||
Altitude | <1000m | |||
Audible noise | ≤55dB | |||
Storage temperature | -15℃~45℃ | |||
Work humidity | 20%~95% | |||
Standard | ||||
EMS/EMI | ||||
Conducted | IEC EN62040-02 | |||
Radiated | ||||
Anti-interference | IEC 61000-4-2.4.5 Level IV, IEC61000-4-3 Level III | |||
Safety | ||||
Safety | GB4943-2001/IEC62040-1 | |||
Transportation | ||||
Drop test | GB-T4857-18 | |||
Vibration test | B-WR1-129(GB-T14715-93) | |||
Machinery features | ||||
Connection | ||||
Inlet | Wiring terminal block | |||
Outlet | Wiring terminal block | |||
External battery slot | Wiring terminal block | |||
Size | ||||
Net Weight and size | ||||
W*D*H(mm) | 260×560X717 | |||
Net W.(Kg) | -- | -- | 6KVA 16或32节7AH电池 | |
G.W. and package size | ||||
W*D*H(mm) | 320×620X840 | |||
G.W.(Kg) | -- | -- | ||
Optional functions | ||||
60Hz | Support | Could be set by software | ||
Converter mode | Support | Could be set by software | ||
ECO mode | Support | Could be set by software | ||
EPO mode | Support | Need to increase related components |