Low Frequency Single Phase 2kva Online Ups

  • Low Frequency Single Phase 2kva Online Ups
  • Low Frequency Single Phase 2kva Online Ups
  • Low Frequency Single Phase 2kva Online Ups
  • Low Frequency Single Phase 2kva Online Ups
  • Low Frequency Single Phase 2kva Online Ups
Low Frequency Single Phase 2kva Online Ups
  • MAXI
  • GUANGDONG
  • ≤100 units 25 days
  • 800 units per month

MXD 11 2KVA Description
MXD 11 2KVA UPS is single phase in & single phase out . Due to its prominent industrial and electronic design, the UPS not only could work safe in the harsh environment, but also could provide maximum protection office automation, network, security applications and industrial applications.

low frequency online ups


  • Single phase in, single phase out

  • Microprocessor control

  • True on-line double conversion design

  • Sine wave pulse width modulation

  • Wide Input voltage windows


2kva ups

single phase upslow frequency online ups

2kva ups

single phase ups


Index

MXD11 2kVA

Comments

Input

Input voltage

Rated voltage

220VAC


Phase

Single phase with ground


Turn on voltage range

220±25% VAC


Bypass voltage range

220VAC±25%

Phase voltage;

Could be adjusted by software.

 

Bypass low loss

165VAC

Bypass low comeback

Low loss +10VAC

Bypass high loss

275VAC

Bypass high comeback

High loss-10VAC

Line low loss/comeback

(165±5) VAC /(180±5) VAC


Line high loss/comeback

(275±5)VAC/(260±5)VAC


Input frequency

Rated frequency

50Hz

Could be adjusted by software.

Frequency low loss

(40~49)±0.2Hz(default:46Hz)

Frequency low comeback

Frequency low loss + 0.5Hz

Frequency high loss

(51~60)±0.2Hz(default:54Hz)

Frequency high comeback

Frequency high loss - 0.5Hz

Input power factor

Input power factor

Max 0.8


Generator

Support generator input

Generator rating≥2*UPS rating

Input current

Rated current

24A


Input protection

Rated protection

32A


Output

Output power

VA/watt

2KVA/1.6kW


Rated voltage

220VAC

Sine wave

Phase

Single phase with ground


Voltage range

200/208/220/230/240VAC

Could be adjusted by software. 10% derating for 208VAC/200VAC.

Voltage regulation

±2%


Voltage distortion

≤8%

Full RCD load

≤3%

Full R load

Index

MXD11 2kVA

Comments

DC offset

≤200mV


Transient response

≤9%

R load 0%~100%~0%

≤6%

R load 20%~100%~20%

Transient recovery

≤60ms voltage recovery to 90%

Full RCD load

Bypass output before turn-on

Yes


Crest ration

3:1


Output frequency range

Line mode

1.Same as input frequency(46Hz~54Hz)


2.50Hz(Input frequency>54Hz or Input frequency<46Hz)


Battery mode

(50+0.1) Hz


Slew rate

1 Hz/Sec


Efficiency

Line mode

> 80%

 R load

Battery mode

> 85%

 R load

Overload

 

line mode/battery mode 

Overload warning only

105%±5%≤load

2Minthen transfer to bypass and alarm.

105%±5%<load≤125%±5%

30S,then transfer to bypass and alarm.

125%±5%<load≤150%±5%

0.5S,then transfer to bypass and alarm.

load>150%±5%

Automatically recovery

Yes


Short protection

Line/battery mode

Cut off output and alarm after 3S


Transfer time

Line to battery mode

0mS


Battery to line mode

0mS


Line to bypass mode

<4mS


Bypass to line mode

<4mS


Battery and charger

Battery

Rated voltage

192VDC


Index

MXD11 2kVA

Comments

Protection

Low alarm voltage / comeback voltage

(180.8V±4V)/ (188.8V±4V)


Shutdown voltage

(176V±4V)/ (184V±4V)

Watt Value < 1000W

(160V±4V)/ (168V±4V)

Watt Value ≥ 1000W

Battery protection

Overcharge protection

(250V±4V)


Battery test

Battery weak

Support


Battery fault

Support


Charger

Output voltage

(220±2)VDC

Float charge voltage

Charge time

Determined by battery capacity


Charging  current

1.2A/5A


Interface

Alarm silence

Support


DC power turn-on

Support


Automatically restart

Support


alarm

Battery mode

Beep/4s


Battery low/charger fault

Beep/1s


UPS fault

Continuously beep


Overload

Beep/1s


Bypass mode

Beep/2Min


Communication

RS232/ RS485 interface

Support


Output dry contactor

Support


Intelligent slot

Support


Monitor software

Appending with UPS


Cooling

Force air cooling

Display

LCD displays UPS status

Support


Index

MXD11 2KVA

Comments

Environment

Work temperature

0℃~40℃


Altitude

<1000m


Audible noise

≤55dB


Storage temperature

-15℃~45℃


Work humidity

20%~95%


Standard

EMS/EMI

Conducted

IEC62040-02


Radiated


Anti-interference

IEC 61000-4-2.4.5 Level IV, IEC61000-4-3 Level III


Safety

Safety

GB4943-2001/IEC62040-1


Transportation

Drop test

GB-T4857-18


Vibration test

B-WR1-129(GB-T14715-93)


Machinery features

Connection

Inlet

Wiring terminal block


Outlet

Wiring terminal block


External battery slot

Wiring terminal block


Size

N.W. and size

L*W*H(mm)

560*260*717


N.W.(Kg)

37/104


G.W. and package size

L*W*H(mm)

630*320*865


weight(Kg)

42/112


Optional functions

60Hz

Support

Could be set by software

Converter mode

Support

Could be set by software

ECO mode

Support

Could be set by software

EPO mode

Support

Need to increase related components